Quality Control

Our QC Program is divided into 2 sections.

Short term test:

A. Done on each pipe
  • Visual Inspection
  • Barcol hardness
  • Wall Thickness
  • Section length
  • Diameter
  • Hydrostatic leak tightness test to 1.5 rated pressure (Only for PN > 6 bar)
  • On random basis
  • Pipe stiffness
  • Axial and circumferential tensile load capacity overall the pipe
B. Type Test (Long Term Test)
  • Strain Corrosion test
  • Hydrostatic Design basis (HDB)